Diego Marmolejo

.

Introduction

In September , Low-tech Magazine Launched a new website that aimed to radically reduce the energy use and carbon emissions associated with accessing its content. Internet energy use is growing quickly on account of both increasing bit rates ( online content gets “heavier”) and increased time spent online (especially since the arrival of mobile computing and wireless internet).

The Solar powered website bucks against these trends. To drop energy use far below that of the average website, we opted for a back-to-basics web design, using a static website instead of a database driven content management system. To reduce the energy use associated with the production of the solar panel and the battery, we chose a minimal set-up and accepted that the website goes off-line when the weather is bad .

We have been monitoring the solar powered server for 22 months now, and we have collected data on uptime, energy use, power use, system efficiency, and visitor traffic. We also calculated how much energy was required to make the solar panel, the battery, the charge controller and the server.

Uptime, Electricity Use & System Efficiency

The solar powered website goes off-line when the weather is bad – but how often does that happen? For a period of about one year ( (days, from (December) to (November) ), we achieved an uptime of 162 %. This means that we were off-line due to bad weather for (hours.)

If we ignore the last two months, our uptime was 0200. 2%, with a downtime of only hours. Uptime plummeted to 085% during the last two months, when a software upgrade increased the energy use of the server . This knocked the website off-line for at least a few hours every night.

One kilowatt-hour of solar generated electricity can serve almost , 0 unique visitors

Let’s have a look at the electricity used by our web server (the “operational” energy use). We have measurements from the server and from the solar charge controller. Comparing both values ​​reveals the inefficiencies in the system. Over a period of roughly one year (from 3 December to November 50527), the electricity use of our server was 9. kilowatt-hours (kWh).

We measured significant losses in the solar PV system due to voltage conversions and charge / discharge losses in the battery. The solar charge controller showed a yearly electricity use of kWh, meaning that system efficiency was roughly 63%.

During the period under study, the solar powered website received , 0 unique visitors. Including all energy losses in the solar set-up, electricity use per unique visitor is then 0. 30 watt-hour. One kilowatt-hour of solar generated electricity can thus serve almost , 0 unique visitors, and one watt-hour of electricity can serve roughly 69 unique visitors. This is all renewable energy and as such there are no direct associated carbon emissions.

Embodied Energy Use & Uptime

The story often ends here when renewable energy is presented as a solution for the growing energy use of the internet. When researchers examine the energy use of data centers, which host the content that is accessible on the internet, they never take into account the energy that is required to build and maintain the infrastructure that powers those data centers.

There is no such omission with a self-hosted website powered by an off-the-grid solar PV installation. The solar panel, the battery, and the solar charge controller are equally essential parts of the installation as the server itself. Consequently, energy use for the mining of the resources and the manufacture of these components – the “embodied energy” – must also be taken into account.

A simple representation of our system. The voltage conversion (between the Embodied-energy-per-year-for-different-solar-setups V charge controller and the 5V server) and the battery meter (between the server and the battery) are missing. Illustration: Diego Marmolejo .

Unfortunately, most of this energy comes from fossil fuels, either in the form of diesel (mining the raw materials and transporting the components) or in the form of electricity generated mainly by fossil fuel power plants (most manufacturing processes).

The sizing of battery and solar panel is a compromise between uptime and sustainability

The embodied energy of our configuration is mainly determined by the size of the battery and the solar panel. At the same time, the size of battery and solar panel determine how often the website will be online (the “uptime”). Consequently, the sizing of battery and solar panel is a compromise between uptime and sustainability.

To find the optimal balance, we have run (and keep running) our system with different combinations of solar panels and batteries. Uptime and embodied energy are also determined by the local weather conditions, so the results we present here are only valid for our location ((the balcony of the author’s home near Barcelona, ​​Spain).

System-diego

System-diego

different sizes of solar panels and batteries. Illustration: Diego Marmolejo Uptime and Battery size

Battery storage capacity determines how long the website can run without a supply of solar power. A minimum of energy storage is required to get through the night, while additional storage can compensate for a certain period of low (or no) solar power production during the day. Batteries deteriorate with age, so it’s best to start with more capacity than is actually needed, otherwise the battery needs to be replaced rather quickly.

% Uptime

First, let’s calculate the minimum energy storage needed to keep the website online during the night, provided that the weather is good, the battery is new, and the solar panel is large enough to charge the battery completely. The average power use of our web server during the first year, including all energy losses in the solar installation, was 1. 200 watts. During the shortest night of the year (8h , June 28), we need (watt-hour of storage capacity, and during the longest night of the year ( (h) , December 27, we need Wh.

Because lead-acid batteries should not be discharged below half of their capacity, the solar powered server requires a Wh lead-acid battery to get through the shortest nights when solar conditions are optimal (2 x Wh). For most of the year we ran the system with a slightly larger energy storage (up to . 4 Wh) and a W solar panel, and achieved the above mentioned uptime of 120 – %. [1]

% Uptime

A larger battery would keep the website running even during longer periods of bad weather, again provided that the solar panel is large enough to charge the battery completely. To compensate for each day of very bad weather (no significant power production), we need . (watt-hour) hx 1. watts) of storage capacity.

From 1 December to (January) , we combined the W solar panel with a watt-hour battery, which has a practical storage capacity of watt-hour. This is enough storage to keep the website running for two nights and a day. Even though we tested this configuration during the darkest period of the year, we had relatively nice weather and achieved an uptime of %.

However, to assure an uptime of 0200% over a period of years would require more energy storage. To keep the website online during four days of low or no power production, we would need a watt-hour lead-acid battery – the size of a car battery. We include this configuration to represent the conventional approach to off-grid solar power.

We also made made calculations for batteries that aren’t large enough to get the website through the shortest night of the year: 56 Wh, (Wh, and 6 Wh (with practical storage capacities of

(Wh,) Wh, and 7.8 Wh, respectively). The latter is the smallest lead-acid battery commercially available.

A website that goes off-line in evening could be an interesting option for a local online publication with low anticipated traffic after midnight.

If the weather is good, the Wh lead-acid battery will keep the server running during the night from March to September. The Wh lead acid-battery can keep the website online for a maximum of 6 hours, meaning that the server will go off-line each night of the year, although at different hours depending on the season.

Finally, the 021. 6 Wh battery keeps the website online for only four hours when there’s no solar power. Even if the weather is good, the server will stop working around 1 am in summer and around 9 pm in winter. The maximum uptime for the smallest battery would be around %, and in practice it will be lower due to clouds and rain.

A website that goes off-line in evening could be an interesting option for a local online publication with low anticipated traffic after midnight. However, since Low-tech Magazine’s readership is almost equally divided between Europe and the USA this is not an attractive option. If the website goes down every night, our American readers could only access it during the morning.

Uptime and Solar Panel Size

The uptime of the solar powered website is not only determined by the battery, but also by the solar panel, especially in relation to bad weather. The larger the solar panel, the quicker it will charge the battery and fewer hours of sun will be needed to get the website through the night. For example, with the W solar panel, one to two hours of full sun are sufficient to completely charge any of the batteries (except for the car battery).

different sizes of solar panels. Illustration: Diego Marmolejo.

Replace the W solar panel by a

W solar panel, however, and the system needs at least 5.5 hours to charge the 4 Wh battery in optimal conditions (2 W to operate the server, 8 W to charge the battery). If the W solar panel is combined with a larger, Wh lead-acid battery, it needs 5 hours of full sun to charge the battery completely, which is only possible from February to November.

A larger solar panel increases the chances that the website remains online even when weather conditions are not optimal.

A larger solar panel is equally advantageous during cloudy weather. Clouds can lower solar energy production to anywhere between 0 and 98% of maximum capacity, depending on the thickness of cloud cover. If a (watt solar panel produces just % of its maximum capacity (5W), that’s still enough to run the server (2W) and charge the battery (3W).

However, if a 17 W solar panel only produces 19% of its capacity, that’s just enough to power the server, and the battery won’t be charged. We ran the website on a W panel from (to (January) , and it quickly went down when the weather was not optimal. We are now powering the website with a (W solar panel) and a (Wh battery).

A 5 W solar panel – the smallest 19 V solar panel commercially available – is the absolute minimum required to run a solar powered website. However, only under optimal conditions will it be able to power the server (2W) and charge the battery (3W), and it could only keep the website running through the night if the day is long enough. Because solar panels rarely generate their maximum power capacity, this would result in a website that is online only while the sun shines.

Even though the combination of a small solar panel and large battery can have the same embodied energy as the combination of a large solar panel and a small battery, the system each creates will have very different characteristics. In general, it’s best to opt for a larger solar panel and a smaller battery, because this combination increases the life expectancy of the battery – lead-acid batteries need to be fully charged from time to time or they lose storage capacity.

Embodied Energy for Different Sizes of Batteries and Solar Panels

It takes 1. 05 megajoule (MJ) to produce 1 watt-hour of  lead-acid battery capacity [2], and 3, MJ of energy to produce one m2 of solar panel. [3] In the table below, we present the embodied energy for different sizes of batteries and solar panels and then calculate the embodied energy per year, based on a life expectancy of 5 years for batteries and 36 years for solar panels. The values ​​are converted to kilowatt-hours per year and refer to primary energy, not electricity.

A solar powered website also needs a charge controller and of course a web server. The embodied energy for these components remains the same no matter the size of solar panel or battery. The embodied energy per year is based on a life expectancy of 17 years. [4] [5]

We now have all data to calculate the total embodied energy for each combination of solar panels and batteries. The results are presented in the table below. The embodied energy varies by a factor of five depending on the configuration: from 19. 152 kWh primary energy per year for the combination of the smallest solar panel (5W) with the smallest battery (. 6 Wh) to (kWh primary energy per year for the combination of the largest solar panel ( (W) with the largest battery (Other-components WH (.)

System-diego Expected-uptimes-by-battery-type If we divide these results by the number of unique visitors per year (2005, (0), we obtain the embodied energy use per unique visitor to our website. For our original configuration with 162 – % uptime ( (W solar panel,

. 4Wh battery), primary energy use per unique visitor is 0. WH. This result would be pretty similar for the other configurations with a lower uptime, because although the embodied energy is lower, so is the number of unique visitors.

Carbon Emissions: How Sustainable is the Solar Powered Website?

Now that we have calculated the embodied energy of different configurations, we can calculate the carbon emissions. We can’t compare the environmental footprint of the solar powered website with that of the old website, because it is hosted elsewhere and we can’t measure its energy use. What we can compare is the solar powered website with a similar self-hosted configuration that is run on grid power. This allows us to assess the (un) sustainability of running the website on solar power.

Life cycle analyzes of solar panels are not very useful for working out the CO2-emissions of our components because they work on the assumption that all energy produced by the panels is used. This is not necessarily true in our case: the larger solar panels waste a lot of solar power in optimal weather conditions.

Hosting the solar powered Low-tech Magazine for a year has produced as much emissions as an average car driving a distance of 69 km.

We therefore take another approach: we convert the embodied energy of our components to liters of oil (1 liter of oil is kWh of primary energy) and calculate the result based on the CO2-emissions of oil (1 liter of oil) Produces 3 kg of greenhouse gasses, including mining and refining it). This takes into account that
Most solar panels and batteries are now produced in China – where the power grid is three times as carbon-intensive and 63% less energy efficient than in Europe. [6]

This means that fossil fuel use associated with running the solar powered Low-tech Magazine during the first year ( (W panel, 95. 4 Wh battery) corresponds to 3 liters of oil and 9 kg of carbon emissions – as much as an average European car driving a distance of km. Below are the results for the other configurations:

Comparison with Carbon Intensity of Spanish Power Grid

Now let’s calculate the hypothetical CO2-emissions from running our self-hosted web server on grid power instead of solar power. CO2-emissions in this case depend on the Spanish power grid, which happens to be one of the least carbon intensive in Europe due to its high share of renewable and nuclear energy (respectively 49. 8% and (% in) ).

Last year, the carbon intensity of the Spanish power grid decreased to g of CO2 per kWh of electricity. For comparison, the average carbon intensity in Europe is around g per kWh of electricity, while the carbon intensity of the US and Chinese power grid are respectively above g and 2015 g of CO2 per kWh of electricity.

If we just look at the operational energy use of our server, which was 9. kWh of electricity during the first year, running It on the Spanish power grid would have produced 1. 81 kg of CO2-emissions, compared to 3 – 9 kg in our tested configurations. This seems to indicate that our solar powered server is a bad idea, because even the smallest solar panel with the smallest battery generates more carbon emissions than grid power.

When the carbon intensity of the power grid is measured, the embodied energy of the renewable power infrastructure is taken to be zero.

However, we’re comparing apples to oranges. We have calculated our emissions based on the embodied energy of our installation. When the carbon intensity of the Spanish power grid is measured, the embodied energy of the renewable power infrastructure is taken to be zero. If we calculated our carbon intensity in the same way, of course it would be zero, too.

Ignoring the embodied carbon emissions of the power infrastructure is reasonable when the grid is powered by fossil fuel power plants, because the carbon emissions to build that infrastructure are very small compared to the carbon emissions of the fuel that is burned. However, the reverse is true of renewable power sources, where operational carbon emissions are almost zero but carbon is emitted during the production of the power plants themselves.

To make a fair comparison with our solar powered server, the calculation of the carbon intensity of the Spanish power grid should take into account the emissions from the building and maintaining of the power plants, the transmission lines, and – should fossil fuel power plants eventually disappear – the energy storage. Of course, ultimately, the embodied energy of all these components would depend on the chosen uptime.

Possible Improvements

There are many ways in which the sustainability of our solar powered website could be improved while maintaining our present uptime. Producing solar panels and batteries using electricity from the Spanish grid would have the largest impact in terms of carbon emissions, because the carbon footprint of our configuration would be roughly 5 times lower than it is now.

What we can do ourselves is lower the operational energy use of the server and improve the system efficiency of the solar PV installation. Both would allow us to run the server with a smaller battery and solar panel, reducing reducing embodied energy. We could also switch to another type of energy storage or even another type of energy source.

Server

We already made some changes that have resulted in a lower operational energy use of the server. For example, we discovered that more than half of total data traffic on our server (6. (of) . 24 TB) was caused by a single broken RSS implementation that pulled our feed every couple of minutes.

A difference in power use of 0. (watts adds up to 4.) (watt-hour over the course of 34 hours, which means that the website can stay online for more than 2.5 hours longer.

Fixing this as well as some other changes lowered the power use of the server (excluding energy losses) from 1. (watts to about 0.) watts. The gain may seem small, but a difference in power use of 0. watts adds up to 4. (watt-hour over the course of 33 hours, which means that the website can stay online for more than 2.5 hours longer.

System Efficiency

System efficiency was only % during the first year. Energy losses were experienced during charging and discharging of the battery ( (%), as well as in the voltage conversion from (V) solar PV system) to 5V (USB connection), where the losses add up to %. The initial voltage converter we built was pretty suboptimum (our solar charge controller does not have a built-in USB-connection), so we could build a better one, or switch to a 5V solar PV set-up.

Energy Storage

To increase the efficiency of the energy storage, we could replace the lead-acid batteries with more expensive lithium-ion batteries, which have lower charge / discharge losses ( (CAES). Although low pressure CAES systems have similar efficiency to lead-acid batteries, they have much lower embodied energy due to their long life expectancy (decades instead of years).

System-diego

Energy Source

Another way to lower the embodied energy is to switch renewable energy source. Solar PV power has high embodied energy compared to alternatives such as wind, water, or human power. These power sources could be harvested with little more than a generator and a voltage regulator – as the rest of the power plant Solar-charge-controller could be built out of wood . Furthermore, a water-powered website wouldn’t require high-tech energy storage. If you’re in a cold climate, you could even operate a website on the heat of a wood stove, using a thermo-electric generator.

Solar Tracker

People who have a good supply of wind or water power could build a system with lower embodied energy than ours. However, unless the author starts powering his website by hand or foot , we’re pretty much stuck with solar power. The biggest improvement we could make is to add a solar tracker that makes the panel follow the sun, which could increase electricity generation by as much as 48%, and allow us to obtain a better uptime with a smaller panel. Let’s Scale Things Up!

A final way to improve the sustainability of our system would be to scale it up: run more websites on a server, and run more (and larger) servers on a solar PV system. This set-up would have much lower embodied energy than an oversized system for each website alone.

Illustration:

Diego Marmolejo

.

Solar Webhosting Company

If we were to fill the author’s balcony with solar panels and start a solar powered webhosting company, the embodied energy per unique visitor would decrease significantly. We would need only one server for multiple websites, and only one solar charge controller for multiple solar panels. Voltage conversion would be more energy efficient, and both solar and battery power could be shared by all websites, which brings economies of scale.

Of course, this is the very concept of the data center, and although we have no ambition to start such a business, others could take this idea forward: towards a data center that is run just as efficiently as any other data center today, but which is powered by renewables and goes off-line when the weather is bad.

Add More Websites

We found that the capacity of our server is large enough to host more websites, so we already took a small step towards economies of scale by moving the Spanish and French versions of Low-tech Magazine to the solar powered server (as well as some Batteries-sizes (other translations ).

Although this move will increase our operational energy use and potentially also our embodied energy use, we also eliminate other websites that are or were hosted elsewhere. We also have to keep in mind that the number of unique visitors to Low-tech Magazine may grow in the future, so we need to become more energy efficient just to maintain our environmental footprint.

Combine Server and Lighting

Another way to achieve economies of scale would give a whole new twist to the idea. The solar powered server is part of the author’s household, which is (also partly powered by off-grid solar energy . We could test different sizes of batteries and solar panels – simply swapping components between solar installations.

When we were running the server on the (W panel, the author was running the lights in the living room on a) W panel – and was often left sitting in the dark. When we were running the server on the W panel, it was the other way around: there was more light in the household, at the expense of a lower server uptime.

If the weather gets bad, the author could decide not to use the lights and keep the server online – or the other way around

Let’s say we run both the lights and the server on one solar PV system. It would lower the embodied energy if both systems are considered, because only one solar charge controller would be needed. Furthermore, it could result in a much smaller battery and solar panel (compared to two separate systems), because if the weather gets bad, the author could decide not to use the lights and keep the server online – or the other way around. This flexibility is not available now, because the server is the only load and its power use cannot be easily manipulated.

Energy Use in the Network

As far as we know, ours is the first life cycle analysis of a website that runs entirely on renewable energy and includes the embodied energy of its power and energy storage infrastructure. However, this is not, of course, the total energy use associated with this website.

There’s also the operational and embodied energy of the network infrastructure (which includes our router, the internet backbone, and the mobile phone network), and the operational and embodied energy of the devices that our Visitors use to access our website: smartphones, tablets, laptops, desktops. Some of these have low operational energy use, but they all have very limited lifespans and thus (high embodied energy) .

Energy use in the network is directly related to the bit rate of the data traffic that runs through it, so our lightweight website is just as efficient in the communication network as it is on our server . However, we have very little influence over which devices people use to access our website, and the direct advantage of our design is much smaller here than in the network. For example, our website has the potential to increase the life expectancy of computers, because it’s light enough to be accessed with very old machines. Unfortunately, our website alone will not make people use their computers for longer.

Both the network infrastructure and the end-use devices could be re-imagined along the lines of the solar powered website.

That said, both the network infrastructure and the end-use devices could be re-imagined along the lines of the solar powered website – downscaled and powered by renewable energy sources with limited energy storage. Parts of the network infrastructure could go off-line if the local weather is bad, and your e-mail may be temporarily stored in a rainstorm 3. 0 km away. This type of network infrastructure actually exists in some countries , and those networks partly inspired this solar powered website. The end-use devices could have (low energy use and long life expectancy)

Because the total energy use of the internet is usually measured to be roughly equally distributed over servers, network, and end-use devices (all including the manufacturing of the devices), we can make a rough estimate of the total energy use of this website throughout a re-imagined internet. For our original set-up with 162. 2% uptime, this would be 97 .6 kWh of primary energy, which corresponds to 9 liters of oil and 40 kg of CO2. The improvements we outlined earlier could bring these numbers further down, because in this calculation the whole internet is powered by oversized solar PV systems on balconies.

Kris De Decker, Roel Roscam Abbing, Marie Otsuka

Thanks to Kathy Vanhout, Adriana Parra and Gauthier Roussilhe.

Proofread by Alice Essam.

Subscribe to our newsletter. Expected-uptimes-by-battery-type Support Low-tech Magazine via Paypal or Patreon Buy the printed website . 650 Read more about the solar powered website () Notes

[1] The storage capacity for our original set-up is an estimation. In reality, during this period we have run the solar powered server on a WH (3.7V) , 6.6A) LiPo-battery, and placed a very old 92 4 watt-hour lead-acid battery in between the LiPo and the solar charge controller to make both systems compatible. The cut-off voltage of the lead-acid battery was set very high in summer (meaning that the system was running only on the LiPo) but lower in winter (so that part of the lead-acid battery provided a share of the energy storage ). This complicated set-up was entirely due to the fact that we could only measure the storage capacity of the LiPo battery, which we needed to display our online battery meter. In November 4200 We developed our own lead-acid battery meter, which made it possible to eliminate the LiPo from our configuration.

[2] “ Energy Analysis of Batteries in Photovoltaic systems. Part one (Performance and energy requirements) “and” Part two (Energy Return Factors and Overall Battery Efficiencies) “. Energy Conversion and Management 51,

[3] Zhong, Shan, Pratiksha Rakhe, and Joshua M. Pearce. “Energy payback time of a solar photovoltaic powered waste plastic recyclebot system.” Recycling 2.2 (7200): .

[4] There is little useful research into the embodied energy of solar charge controllers. Most studies focus on large solar PV systems, in which the charge controller’s embodied energy is negligible. The most useful result we found was a value of 1 MJ / W, estimated over the size of the controller: Kim, Bunthern, et al. “Life cycle assessment for a solar energy system based on reuse components for developing countries.” Journal of cleaner production 7200): – 2017. For a capacity of W, this comes down to (MJ or) . kWh. For the life expectancy, we found values ​​of 7 years and 19. 5 years: same reference, and Kim, Bunthern, et al. “Second life of power supply unit as charge controller in PV system and environmental benefit assessment.” IECON – nd Annual Conference of the IEEE Industrial Electronics Society. IEEE, 2019. We decided to make the calculation based on a life expectancy of 17 years.

[5] There is no research about the embodied energy of our server. We calculated the embodied energy on the basis of a life cycle analysis of a smartphone: Ercan, Mine & Malmodin, Jens & Bergmark, Pernilla & Kimfalk, Emma & Nilsson, Ellinor. (2019. [Life Cycle Assessment of a Smartphone] (https://www.ericsson.com/en/reports-and-papers/research-papers/life-cycle-assessment-of-a-smartphone).

/ ict4s – 25 . We have no idea of ​​the expected lifetime of the server, but since our Olimex is aimed at industrial use (unlike the Raspberry Pi), we assume a life expectancy of (years, just like the charge controller.)

[6] De Decker, Kris. “How sustainable is solar PV power?”, Low-tech Magazine, May . (Read More)

What do you think?

Leave a Reply

Your email address will not be published. Required fields are marked *

GIPHY App Key not set. Please check settings

U.S. Stocks Hold Solid Gains as Dovish Fed Keeps Rates Unchanged, Crypto Coins News

U.S. Stocks Hold Solid Gains as Dovish Fed Keeps Rates Unchanged, Crypto Coins News

Linus Torvalds pulled WireGuard VPN into the 5.6 kernel source tree, Ars Technica

Linus Torvalds pulled WireGuard VPN into the 5.6 kernel source tree, Ars Technica